Kinco G2100E 10.1-inch HMI panel, representative front appearance, gray bezel with silver horizontal trim

Kinco G2100E 10.1-inch HMI panel: representative front appearance; confirm the full model code and specifications for interface and configuration differences.

Standard SERIES · G2100E

Kinco G2100E / G2100E-4G / G2100E-WIFI / G2100E2 10.1-inch HMI Panel

Model codes: G2100E | G2100E-4G | G2100E-WIFI | G2100E2

The Kinco G2100E group provides a 10.1-inch 1024 × 600 display and a 280 × 193 × 36 mm body. Consider it for a larger DTools Pro interface where network topology drives the ordering choice. The E2 variant has two Ethernet ports; base, Wi-Fi and 4G codes list one each. Confirm wireless coverage or cellular bands only for the chosen suffix, then measure the 260 × 179 mm opening and check the PLC driver against the selected hardware.

Generation: Green Series 2 (G2) in the Standard series

10.1" display · 1024 × 600Resistive touchQuad-core ARM 1.5 GHz1 Ethernet port and 3 serial ports

Choose from 4 model variants with the same display size and resolution. Confirm the exact code on the cabinet label before ordering.

Available for quotation — specify the full code, quantity and destination.

Supplied by CINKR. Confirm the panel cut-out, the interfaces and the protocol before ordering.

EXACT MODEL CODE

Compare G2100E model codes

Match the full code to the PLC connection, project software and cabinet opening. An option listed for one code does not apply to every code on this page.

Per-code connection and mechanical requirements
Full model codeSerial portsEthernetWi-Fi4GInput powerCut-outBody W × H × DSoftware
G2100ECOM0: RS232/RS485/RS422 · COM1: RS485 COM2:RS2321 portNot offered on this modelNot offered on this modelDC 18 to 28 V260 × 179 mm280 × 193 × 36 mmKinco DTools Pro
G2100E-4GCOM0: RS232/RS485/RS422 · COM1: RS485 COM2:RS2321 portNot offered on this modelLTE-FDD Band 1/3/5/8, LTE-TDD Band 34/38/39/40/41DC 18 to 28 V260 × 179 mm280 × 193 × 36 mmKinco DTools Pro
G2100E-WIFICOM0: RS232/RS485/RS422 · COM1: RS485 COM2:RS2321 portIEEE 802.11 b/g/nNot offered on this modelDC 18 to 28 V260 × 179 mm280 × 193 × 36 mmKinco DTools Pro
G2100E2COM0: RS232/RS485/RS422 · COM1: RS485 COM2:RS2322 portsNot offered on this modelNot offered on this modelDC 18 to 28 V260 × 179 mm280 × 193 × 36 mmKinco DTools Pro
G2100E panel opening illustration260 mm cut-out width179 mm cut-out heightG2100E
Illustrative opening for the base code. Use the applicable dimension drawing to machine the panel; this sketch does not show connector positions or pinout.

Before fitting the panel

Base-code opening
260 × 179 mm
Body dimensions
280 × 193 × 36 mm
Power supply
DC 18 to 28 V
Project software
Kinco DTools Pro

Check door thickness, clip access, ventilation and cable bend clearance. Compare the full variant code before reusing an opening or cable.

Request the applicable installation drawing →

PRODUCT GUIDE

About the G2100E | G2100E-4G +2 codes

The Kinco G2100E group provides a 10.1-inch 1024 × 600 display and a 280 × 193 × 36 mm body. Consider it for a larger DTools Pro interface where network topology drives the ordering choice. The E2 variant has two Ethernet ports; base, Wi-Fi and 4G codes list one each. Confirm wireless coverage or cellular bands only for the chosen suffix, then measure the 260 × 179 mm opening and check the PLC driver against the selected hardware.

G2100E-4G adds 4G. G2100E-WIFI adds Wi-Fi. G2100E2 has 2 Ethernet ports.

QUICK DECISION

Know where this panel fits before you compare specifications.

BEST FIT

Choose G2100E | G2100E-4G +2 codes when you need:

  • A 10.1-inch G2 group with wired, Wi-Fi, 4G and E2 variants; a shared screen size does not mean shared wiring.
  • Use 260 × 179 mm for the cabinet opening and 280 × 193 × 36 mm for body clearance. The DC 18 to 28 V supply must match the exact panel label.

CHECK BEFORE ORDERING

Confirm these details first:

  • 4 model codes (G2100E | G2100E-4G | G2100E-WIFI | G2100E2) share this display size and resolution; confirm which code matches the cabinet label.
  • Compare the published panel cut-out and panel body depth with the opening and the space behind the machine door.
  • Check the protocol and connector arrangement the machine program expects against the published interface set.

CONSIDER ANOTHER CODE IF

Your machine instead requires:

  • Choose another model if the opening, software family or required PLC driver differs. Compare GL2100E, GT2100E, GL100 before changing the machine design.

The Kinco G2100E group provides a 10.1-inch 1024 × 600 display and a 280 × 193 × 36 mm body. Consider it for a larger DTools Pro interface where network topology drives the ordering choice. The E2 variant has two Ethernet ports; base, Wi-Fi and 4G codes list one each. Confirm wireless coverage or cellular bands only for the chosen suffix, then measure the 260 × 179 mm opening and check the PLC driver against the selected hardware.

Model codes: G2100E | G2100E-4G | G2100E-WIFI | G2100E2.

Kinco G2100E HMI Panel Overview

Industrial control systems depend heavily on reliable human-machine interface terminals to bridge automation logic with daily machine operations. The Kinco G2100E / G2100E-4G / G2100E-WIFI / G2100E2 10.1-inch HMI Panel provides plant operators and maintenance engineers with a dependable visual workstation designed specifically for industrial manufacturing environments. Rather than evaluating automation hardware purely on diagonal display size, engineers must assess display resolution, interface channel allocations, physical enclosure clearances, and the exact software runtime environment. A properly selected control terminal ensures rapid error identification, streamlined batch execution, and consistent operator workflow across demanding continuous production environments.

Operating conditions on factory floors involve electrical interference, continuous mechanical vibrations, and wide temperature swings. This industrial terminal incorporates robust electrical isolation, industrial-grade power supply conditioning, and a durable front bezel gasket that seals against dust, moisture, and cutting fluid mist. The resistive touchscreen interface guarantees dependable touch actuation whether operators use bare hands or heavy protective safety gloves. Integrating this hardware into an existing or new electrical cabinet ensures long-term operational stability and predictable control behavior across automated machinery lines.

G2100E for Larger Operator Views and Network Choices

Operator screens on this 10.1-inch display balance visual workspace with moderate enclosure footprint. The 1024 × 600 widescreen resolution enables machine builders to arrange interactive motor controls, sensor diagnostic tables, and visual warning panels across clear zones. Field operators benefit from comfortable touch targets that reduce inadvertent keying errors during continuous manufacturing shifts.

Visual ergonomics play an essential role in minimizing machine downtime during complex industrial operations. Operator screens designed for this terminal benefit from structured visual zoning where primary machine metrics, axis coordinates, and emergency interlock states remain immediately identifiable. Secondary configuration parameters, batch recipe parameters, and historical diagnostic trends are organized systematically on contextual sub-pages. By keeping critical alarms visible without cluttering operator workspaces, engineering teams build interfaces that facilitate rapid technician response and improve overall equipment effectiveness on active production lines.

G2100E Wireless Variants and Dual-Port E2 Hardware

Hardware features vary across specific model suffixes. Standard G2100E includes a single 10/100M Ethernet port, G2100E-WIFI adds 2.4 GHz wireless networking, G2100E-4G integrates cellular data modem capabilities, and G2100E2 incorporates dual independent Ethernet controllers. All models feature 512 MB RAM, 4 GB eMMC flash storage, and a robust 4-wire resistive touch interface powered by a nominal 24 V DC supply.

Internal computing hardware balances processing performance with industrial thermal dissipation requirements. High-capacity non-volatile flash storage reliably preserves operational recipes, detailed event histories, graphical symbols, and multilingual font libraries through sudden plant power failures. Dedicated graphics acceleration handles real-time trend visualization and dynamic object updates smoothly while communication tasks poll connected controllers concurrently. Automation engineers can design comprehensive machine diagnostics and data-logging routines without compromising visual refresh rates or communications responsiveness.

G2100E PLC Ports and Driver Checks

Match G2100E PLC Drivers and Cable Pinout

Achieving seamless communication between this operator interface and factory floor automation equipment requires verifying communication protocols, serial parameters, and controller addressing modes. A matching physical connector such as a standard DB9 port or an RJ45 Ethernet jack provides hardware connectivity but does not ensure software driver compatibility. Engineering teams must confirm that the specific controller CPU, firmware version, and communication card are fully supported by the configuration runtime before proceeding with on-site installation and field wiring.

Serial communication ports require precise configuration of baud rates, parity bits, stop bits, and station numbering to establish reliable data polling loops. For network-connected models, network topologies, subnet routing, and gateway parameters must be documented thoroughly. Industrial engineers should confirm whether communication links operate point-to-point or share multidrop buses with third-party instruments, ensuring that driver polling timeouts and retry counters are calibrated properly to prevent communication dropouts under high electrical noise conditions.

G2100E 260 × 179 mm Cut-out and Body Dimensions

Measure the 260 × 179 mm Opening for G2100E

Enclosure preparation requires an exact 260 × 179 mm rectangular cut-out. The front bezel measures 280 × 193 mm with an overall chassis depth of 36 mm. Engineering layouts must preserve at least 30 mm of rear clearance behind the enclosure door to accommodate serial DB9 connectors, Ethernet patch cords, and DC power terminal blocks without excessive cable strain.

Proper cabinet cut-out preparation is critical to achieving an IP65 front environmental seal. Field technicians must machine the enclosure door according to precise cutout tolerances and ensure that mounting surfaces are flat, deburred, and free of metal filings. When securing the terminal with its mounting brackets, uniform torque should be applied in opposing pairs to compress the sealing gasket evenly around the perimeter. Uneven clamping forces can distort the front bezel or pinch the internal seal, compromising long-term ingress protection against coolants and washdown sprays.

DTools Pro Software for G2100E

Select the G2100E Target in DTools Pro

Application programming is carried out in Kinco DTools Pro. System integrators must verify that communication drivers within DTools Pro support the target controller protocols over RS232, RS485, or Ethernet links. Dual-port E2 variants enable physical separation between internal automation machine subnets and supervisory SCADA networks.

Project engineering and runtime configuration follow established development workflows. Integrators should refer to the Kinco HMI DTools software download guide to obtain current programming packages and verified driver libraries. For protocol integration, consult the Kinco HMI PLC compatibility guide to verify register mapping rules, and utilize the Kinco HMI PLC no response troubleshooting guide when diagnosing physical cabling, station addressing, or driver timeout faults during machine commissioning.

G2100E Existing-Panel Fit and Project Checks

Migrating from older 10.1-inch operator terminals requires verifying panel cut-outs and communication pinouts. Check existing project tags, alarm boundaries, and macro routines in DTools Pro to ensure uninterrupted functionality. Compare physical dimensions and software features against sibling models before finalizing machine retrofit bills of materials.

Modernizing legacy automation equipment or replacing damaged panels requires a methodical audit of dimensions, interface hardware, and project software compatibility. Review the HMI panel replacement checklist to systematically compare cut-out openings, power terminal requirements, serial pinouts, and program conversion requirements. For alternative machine design considerations or sibling model comparisons, evaluate the Kinco GL2100E HMI Panel, Kinco GT2100E HMI Panel, and Kinco G100 HMI Panel to verify appropriate mechanical fit and communication capabilities.

Software conversion from legacy runtime files involves more than compiling projects for new hardware targets. Graphical objects, variable scaling, alarm groupings, and communication driver blocks must be inspected individually in the configuration software. Always retain the original unedited project backup and archive working machine parameters before executing changeover tasks. Running side-by-side bench verification with a secondary PLC confirms that numerical scaling, multi-byte word ordering, and recipe transfer operations function identically to the original equipment.

G2100E Price and Quotation Details

Procurement specialists should define the required communication suffix—standard Ethernet, Wi-Fi, 4G, or dual-Ethernet E2—prior to requesting pricing. Unit availability, lead times, and technical documentation are confirmed through formal commercial quotation, ensuring appropriate hardware delivery for production schedules.

Industrial procurement decisions require clear verification of part numbers, expected quantities, regional logistics, and formal commercial terms. Pricing and lead-time schedules are handled via professional inquiry to ensure technical specialists verify application parameters, documentation availability, and shipment details prior to order finalization. machine builder builders and maintenance teams should submit complete machine requirements—including controller model, power supply configuration, and destination country—to receive an official quotation and comprehensive technical evaluation.

Frequently Asked Questions

How do G2100E, G2100E-4G, G2100E-WIFI, and G2100E2 differ?

G2100E provides single Ethernet; G2100E-WIFI adds wireless LAN; G2100E-4G adds an integrated cellular modem; G2100E2 provides dual independent Ethernet network ports.

What cut-out and cabinet dimensions are required for G2100E?

The mounting cut-out is 260 × 179 mm. The outer bezel is 280 × 193 mm with a 36 mm chassis depth. Provide at least 30 mm of rear depth clearance for industrial cabling.

How do I check PLC driver compatibility for G2100E models?

Open Kinco DTools Pro, select your exact G2100E variant in the hardware catalog, assign controller communication drivers, and verify communication parameters before field deployment.

How can I request official datasheets, manuals, or quotations?

Send an inquiry detailing your desired suffix code, order volume, and destination to receive official dimensional drawings, programming guides, and a competitive commercial quotation.

SELECTION CHECKLIST

Confirm a G2100E before ordering

  1. Measure the panel openingCompare the machine opening with the published 260 × 179 mm cut-out and the 280 × 193 × 36 mm panel body.
  2. List the required portsWrite down every protocol and connector the cabinet uses, then compare them with the published interface set: 1 Ethernet port, 3 serial ports, 1 USB host port, Wi-Fi on G2100E-WIFI and 4G on G2100E-4G.
  3. Confirm the program and protocolCheck which configuration software and protocol the machine program expects, then confirm the variant code that matches it.

SPECIFICATIONS

G2100E | G2100E-4G +2 codes Technical Specifications

Compare specifications by model code, including differences in interfaces, power requirements and dimensions.

Model codesG2100E | G2100E-4G | G2100E-WIFI | G2100E2 · 4 codes that share the display size and resolution
SeriesStandard series · Green Series 2 (G2)
Interface summaryG2100E1 port · 3 serial portsG2100E-4G1 port · 3 serial ports · 4GG2100E-WIFI1 port · 3 serial ports · Wi-FiG2100E22 ports · 3 serial ports
Display
Display size10.1"
Resolution1024 × 600
Display area222.72 × 125.28 mm (H × V)
Colours16.7 million colours
Viewing angle85/85/85/85 (T/B/L/R)
Contrast ratio500:1
BacklightLED
Brightness300 cd/m²
Backlight life30,000 hours
Touch panel4-wire resistive
Hardware
ProcessorQuad-core ARM 1.5 GHz
RAM512 MB
Flash storage4 GB
USB host1 port
USB device1 port
SD cardNot offered on this model
Interfaces
EthernetG2100E1 portG2100E-4G1 portG2100E-WIFI1 portG2100E22 ports
Serial portsCOM0: RS232/RS485/RS422 · COM1: RS485 COM2:RS232
CANopenNot offered on this model
Wi-FiG2100ENot offered on this modelG2100E-4GNot offered on this modelG2100E-WIFIIEEE 802.11 b/g/nG2100E2Not offered on this model
4GG2100ENot offered on this modelG2100E-4GLTE-FDD Band 1/3/5/8, LTE-TDD Band 34/38/39/40/41G2100E-WIFINot offered on this modelG2100E2Not offered on this model
HDMINot offered on this model
RFIDNot offered on this model
Power
Input powerDC 18 to 28 V
Power consumption7W at 24 V DC
Allowable power loss< 3ms
Insulation resistance> 50 MΩ at 500 V DC
Dielectric strength500 V AC for 1 minute
Power isolationNot offered on this model
Serial port isolationNot offered on this model
Mechanical
EnclosureEngineering plastic
Panel dimensions280 × 193 × 36 mm
Panel cut-out260 × 179 mm
MountingPanel mounting
Front protectionIP65 (front panel)
PCB coatingNot offered on this model
Environment
Operating temperature0 to 50 °C
Operating humidity10 to 90 % RH (non-condensing)
Storage temperature-20 to 60 °C
Storage humidity10 to 90 % RH (non-condensing)
Vibration resistance10-500 Hz, 30 m/s², 1 hour each for X, Y, Z directions
CoolingNatural air circulation
Certification and software
Manufacturer-listed CE standardsEN 61000-6-4:2019, EN 61000-6-2:2019
Configuration softwareKinco DTools Pro
Remote maintenanceEdgeAccess 2.0

COMPARE RELATED PANELS

Compare G2100E | G2100E-4G +2 codes with Related Panels.

Related model codes help you avoid choosing a neighbouring size by accident. A different series or generation is not a substitute without a cut-out and port check.

ModelCut-outDisplaySoftwarePortsRelationship
G2100E | G2100E-4G +2 codes260 × 179 mm10.1"Kinco DTools Pro1 port · 3 serial ports · Wi-Fi on G2100E-WIFI · 4G on G2100E-4GSelected code
GL2100E | GL2100E-4G | GL2100E-WIFI260 × 179 mm10.1"Kinco DTools Pro1 port · 3 serial ports · Wi-Fi on GL2100E-WIFI · 4G on GL2100E-4GDifferent series — confirm the cut-out, the protocol and the ports before substituting.
GT2100E260 × 179 mm10.1"Kinco DTools1 port · 3 serial portsSame series, different generation — check the cut-out, ports and panel depth.
GL100 | GL100E260 × 179 mm10.1"Kinco DTools2 serial ports · Ethernet on GL100EDifferent series — confirm the cut-out, the protocol and the ports before substituting.

Related model codes show a size and interface comparison, not interchangeability. Confirm the cut-out, the port arrangement and the protocol before treating a neighbouring code as a replacement.

DOWNLOADS

G2100E | G2100E-4G +2 codes Manuals, Drawings & Software

Request the manual or dimension drawing for the full model code and hardware revision. Use the manufacturer download center for software, then check its supported target and release.

Include your full model code, revision and required document language.

G2100E manual

Operating instructions, parameter references and panel setup information.

Model codes: G2100E / G2100E-4G / G2100E-WIFI / G2100E2

G2100E dimension drawing

Panel outline, panel cut-out and depth drawing for the machine door.

Model codes: G2100E / G2100E-4G / G2100E-WIFI / G2100E2

Kinco DTools Pro software

Kinco DTools Pro project software; check the target and package release.

Model codes: G2100E / G2100E-4G / G2100E-WIFI / G2100E2

Kinco DTools Pro — manufacturer downloads

Kinco DTools Pro project software; check the target and package release.

Model codes: G2100E / G2100E-4G / G2100E-WIFI / G2100E2

V1.10.0.2 (Build260821) · checked 2026-10-05

Official manufacturer download center

FAQ

G2100E | G2100E-4G +2 codes — Questions to Check Before Ordering.

How do G2100E, G2100E-4G, G2100E-WIFI, G2100E2 differ?

See product specifications and technical documentation for details.

What cut-out and rear clearance does G2100E need?

See product specifications and technical documentation for details.

How do I check G2100E against my PLC driver and project?

See product specifications and technical documentation for details.

How can I request a G2100E datasheet, manual or quotation?

See product specifications and technical documentation for details.

REQUEST A QUOTE

Request a Quote for the G2100E

Tell us whether the G2100E is for a new machine, an upgrade or a replacement, and include the panel opening and the interfaces in use. This form only prepares your message; nothing is submitted or stored.

Machine or replacement details (optional)
Email CINKR About G2100E